Enterasys Enterasys SecureStack B2 B2G124-24 Specifikace Strana 74

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 600
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 73
clear summertime
3-22 Basic Configuration
Parameters
Defaults
Ifanoffsetisnotspecified,nonewillbeapplied.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowsetdaylightsavingstimetorecurstartingonthefirstSundayofAprilat
2a.m.andendingthelastSundayofOctoberat2a.m.withanoffsettimeofonehour:
B2(su)->set summertime recurring first Sunday April 02:00 last Sunday October
02:00 60
clear summertime
Usethiscommandtoclearthedaylightsavingstimeconfiguration.
Syntax
clear summertime
Parameters
None.
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoclearthedaylightsavingstimeconfiguration:
B2(su)->clear summertime
start_week Specifiestheweekofthemonth torestartdaylightsavingstime.Valid
valuesare:first,second,third,fourt h ,and last.
start_day Specifiesthedayoftheweektorestartdaylightsaving stime.
start_hr_min Specifiesthetimeofdaytorestartdaylightsavingstime.Formatis
hh:mm.
end_week Specifiestheweekofthe
monthtoenddaylightsavingstime.
end_day Specifiesthedayoftheweektoenddaylightsavingstime.
end_hr_min Specifiesthetimeofdaytoenddaylightsavingstime.Formatishh:mm.
offset_minutes (Optional)Specifiestheamountoftimeinminutestooffsetdaylight
savingstimefromthenondaylightsavingstimesystem
setting.Valid
valuesare1‐1440.
Zobrazit stránku 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 599 600

Komentáře k této Příručce

Žádné komentáře