Enterasys Enterasys SecureStack B2 B2G124-24 Specifikace Strana 128

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 600
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 127
set ciscodp holdtime
6-10 Discovery Protocol Configuration
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosettheCiscoDPtimerto120second s.
B2(su)->set ciscodp timer 120
set ciscodp holdtime
Usethiscommandtosetthetimetolive(TTL)forCiscodiscoveryprotocolPDUs.Thisisthe
amountoftime,insecond s,neighboringdeviceswillholdPDUtransmissionsfromthesending
device.
Syntax
set ciscodp holdtime hold-time
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtosetCiscoDPholdtimeto180seconds:
B2(su)->set ciscodp hold-time 180
set ciscodp port
Usethiscommandtosetthestatus,voiceVLAN,extendedtrustmode,andCoSpriorityfor
untrustedtrafficfortheCiscoDiscoveryProtocolononeormoreports.
Syntax
set ciscodp port {[status {disable | enable}] [vvid {vlan-id | none | dot1p |
untagged}] [trusted {yes | no}] [cos value]} port-string
seconds SpecifiesthenumberofsecondsbetweenCiscoDPPDU transmissions.
Validvaluesarefrom5to254seconds.
holdtime SpecifiesthetimetoliveforCiscoDPPDUs.Validvaluesarefrom10to255
seconds.
Zobrazit stránku 127
1 2 ... 123 124 125 126 127 128 129 130 131 132 133 ... 599 600

Komentáře k této Příručce