Recommended Shutdown Procedure Using OFFLINE/RESET Switch
4-8 Troubleshooting
Recommended Shutdown Procedure Using OFFLINE/RESET
Switch
BeforepullingaDFEmoduleoutofachassis,
pressortaponitsOFFLINE/RESETswitchforlessthan1 second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indi cating
thattheDFEmoduleisshuttingdown.AttheendoftheDFEmoduleshutdownroutine,
the
CPULEDchangestoa67%/33%sequenceofamber/off,respectively,indicatingthe
moduleisinahaltstate.InthistimeitissafetorestartorremovetheDFEmodulefrom
thechassis.
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESETswitch,youhave60
secondsfromthetime
theCPUstartsflashingamber/offuntiltheti me thedeviceis
automaticallyrestarted.
Last Resort Shutdown Procedure Using OFFLINE/RESET
Switch
ToresetaDFEmodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe OFFLINE/RESETswitchforapproximately6seconds.
PullinganyDFEmoduleoutofthechassisbeforeithasbeenshut downisnot
recommended.Theonlysafetimetopullamoduleoutofthechassis
isafterthe
completionofashutdownandthemanagementLEDisflashingamber/off.
Caution: Do not pull any DFE-Platinum module out of an operating chassis before it has
completed its shutdown routine.
Precaución: No retire los módulos DFE-Platinum del chasis en funcionamiento hasta
que no se haya terminado con la rutina de apagado.
Note: The only safe time to pull a DFE module out of the chassis is when the CPU LED is
blinking amber. Otherwise, system operation will be interrupted.
Caution: This method of shutting down a DFE-Platinum module is not recommended
except as a last resort, because all processes currently running on the module will be
interrupted resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos
DFE-Platinum. Recurra a él sólo como último recurso, puesto que interrumpe todos los
procesos del módulo en funcionamiento, lo que podría resultar pérdidas de frames.