Port Priority and Rate Limiting Configuration Command Set
Configuring Port Priority
SecureStack A2 Configuration Guide 8-3
8.3.1.1 show port priority
Use this command to display the 802.1D priority for one or more ports.
show port priority [port-string]
Syntax Description
Command Defaults
If port-string is not specified, priority for all ports will be displayed.
Command Mode
Read-Only.
Example
This example shows how to display the port priority for the fe.2.1 through 5:
port-string (Optional) Displays priority information for a specific port.
For a detailed description of possible port-string values,
refer to Section 3.1.1.
A2(rw)->show port priority fe.2.1-5
fe.2.1 is set to 0
fe.2.2 is set to 0
fe.2.3 is set to 0
fe.2.4 is set to 0
fe.2.5 is set to 0